EFEKTIVITAS FLUID DAN BLANKET WARMER TERHADAP SUHU TUBUH PASIEN HIPOTERMI POST ANESTESI SUBARACHNOID BLOCK Studi di Recovery Room RSUD Dr. Mohamad Soewandhie Surabaya

MAHIN, AHMAD (2023) EFEKTIVITAS FLUID DAN BLANKET WARMER TERHADAP SUHU TUBUH PASIEN HIPOTERMI POST ANESTESI SUBARACHNOID BLOCK Studi di Recovery Room RSUD Dr. Mohamad Soewandhie Surabaya. Skripsi thesis, STIKES MAJAPAHIT.

[img] Text
1. Cover Depan Full.pdf

Download (686kB)
[img] Text
2. Bab 1 - 5 Full.pdf

Download (805kB)
[img] Text
JURNAL SKRIPSI - AHMAD MAHIN - up.doc

Download (1MB)
Official URL: http://repo.stikesmajapahit.ac.id

Abstract

ABSTRACT Subarachnoid block anesthesia can caused postoperative hypothermia. Hypothermia caused discomfort to patients and created dangerous complications. Handling of non-pharmacological hypothermia included using fluid warmers and blanket warmers. The purpose of this study was to determine the differences in the effectiveness of fluid warmers and blanket warmers on the body temperature of hypothermic patients after subarachnoid block anesthesia. This research was a quasy experimental study with a non-equivalent comparison group design. The research subjects included hypothermic patients after subarachnoid block anesthesia at Recovery Room RSUD Dr. Mohamad Soewandhie Surabaya. The sample consisted of 82 people divided into 2 groups, 41 people in the fluid warmer group and 41 people in the blanket warmer group. The infusion fluid used was B Braun brand Ringer Lactate electrolyte fluid with a fluid dose of 50 ml/kg Body Weight/24 hours. While the duration of gave fluid and blanket warmer is 30 minutes with a frequency of 1 time. The sampling technique used was Simple Random Sampling. Data analysis used the Paired T-Test and the Independent T-test. The results showed that after 30 minutes, the average increased in body temperature in the fluid warmer group was 1.78oC, the average increased in body temperature in the blanket warmer group was 1.18oC, and the difference in the average value of body temperature increased between the fluid warmer and blanket warmer groups was 0,59oC. The p value on the results of the Independent T-Test was 0.000. Based on the basis of decision making on the Independent T-Test, the p value was less than 0.05, This means that the average value of body temperature increased between the fluid warmer group and the blanket warmer group was significantly different. Saw the results of the above study, it can be concluded that there were differences in the effectiveness of fluid warmers and blanket warmers on the body temperature of hypothermic patients after subarachnoid block anesthesia. Keywords: Hypothermia, subarachnoid block anesthesia, fluid, blanket warmer

Item Type: Thesis (Skripsi)
Subjects: R Medicine > RT Nursing
Divisions: Faculty of Medicine, Health and Life Sciences > School of Medicine
Depositing User: Unnamed user with email libstikesmajapahit@gmail.com
Date Deposited: 21 Nov 2023 03:21
Last Modified: 21 Nov 2023 03:21
URI: http://repo.stikesmajapahit.ac.id/id/eprint/488

Actions (login required)

View Item View Item